Unit Conversion Tables: Every Electrical Quantity
The complete SI prefix set, the base and derived units behind every major electrical quantity, and the confusing pairs that cause real errors — with an interactive converter and worked examples.
1. Why unit conversion matters when reading schematics
A schematic is a compressed language. The same digit 5 on a net can mean 5 V on a supply rail, 5 kΩ on a resistor, or 5 nF on a decoupling capacitor — the prefix between the number and the unit is what carries the magnitude. Conversion tables exist to let you move between those magnitudes on demand, so you can confirm that a 4.7 kΩ resistor is the same part as a 4700 Ω one, or that a 100 nF capacitor matches the 0.1 μF value called out in a datasheet.
Getting a prefix wrong is the classic silent error in electronics: nothing crashes, but every dependent calculation shifts by a factor of ten, a hundred, or a thousand. The tables below cover the complete SI prefix set, the units behind every major electrical quantity, and the pairs that are most often confused. An interactive converter at the bottom does the arithmetic for you, and a worked circuit shows how voltage, current, resistance and power relate in real units. Use the on‑page index to jump to any quantity.
2. The SI system: base and derived units
The International System of Units (SI) defines seven base quantities — length (metre), mass (kilogram), time (second), electric current (ampere), temperature (kelvin), amount of substance (mole) and luminous intensity (candela). Almost everything in an electrical schematic is a derived unit built from these: the volt is watts per ampere, the ohm is volts per ampere, the watt is joules per second, the farad is coulombs per volt, the henry is volt‑seconds per ampere, and the coulomb is ampere‑seconds. Because the system is coherent, these line up exactly — 1 W = 1 V·A = 1 J/s — so a conversion is only correct if the base dimensions match on both sides.
Derived units matter because they let you verify a conversion by dimensional analysis. If you claim “1 Wh = 3600 J”, you can check it: 1 W = 1 J/s, one hour = 3600 s, so 1 Wh = 1 J/s × 3600 s = 3600 J. That cross‑check catches most mistakes before they reach a board. When a quantity on a schematic is unfamiliar, writing out its base dimensions (kg, m, s, A) is the fastest way to confirm a table entry — or to see that two apparently different units are actually the same.
3. SI prefixes & engineering notation
A prefix is a shorthand for a power of ten attached to a unit: kilo (k) means ×10³, milli (m) means ×10⁻³, so 1 kΩ = 1000 Ω and 1 mA = 0.001 A. The prefixes that actually appear on schematics cluster in groups of three — kilo/mega/giga on the large side, milli/micro/nano on the small — which matches the three‑significant‑figure values most components come in. This is engineering notation, where the exponent is always a multiple of three, and it is why a resistor is written 4.7 kΩ (not 4.7×10³ Ω) and a capacitor 100 nF (not 1×10⁻⁷ F).
The full set spans twenty‑four named prefixes, from quetto? — quecto (q, 10⁻³⁰) up to quetta (Q, 10³⁰), with the four extreme values (r, q, R, Q) added in the 2022 SI revision. You will meet the middle of that range daily; the extremes mostly live in metrology and physics. The reference table in section 19 lists every prefix with its symbol, multiplier, scientific and decimal forms, and a worked example — it is sortable and searchable, and each symbol can be copied.
4. How to read a prefixed value
Reading a prefixed value is a three‑step habit: take the number, read the prefix, read the unit. 4.7 kΩ is 4.7 × 10³ Ω = 4700 Ω. 3.3 V is just 3.3 volts (no prefix). 100 nF is 100 × 10⁻⁹ F = 1×10⁻⁷ F = 0.1 μF. Before any calculation it is usually safest to convert everything to the base unit (Ω, V, A, F), do the arithmetic in base units, then express the answer in whichever prefix keeps the number between roughly 0.1 and 1000.
Capitalization is not decorative — it changes the value by a factor of a million. Uppercase M is mega (10⁶); lowercase m is milli (10⁻³) — so MΩ and mΩ differ by 10⁹. T is tera (10¹²) and there is no lowercase “t” prefix at all. The micro prefix is the Greek mu μ (10⁻⁶), written μF, μH, μA, μs — not “mF”, which would be millifarad (10⁻³ F), a thousand times larger. When a font makes “μ” and “m” look alike, zoom in: a 0.1 μF capacitor is not a 0.1 mF one.
5. Voltage, current & charge
Voltage (symbol V, unit the volt) is the potential difference that pushes current; on a schematic it appears as rail labels (+5 V, 3V3, VCC, GND), a battery or supply symbol, or a measured node. The practical prefixes are kV, V, mV and μV: mains is hundreds of volts, logic rails are single‑digit volts, sensor and audio signals are millivolts, and op‑amp offsets are microvolts. Because voltage is so central, almost every other quantity is quoted relative to it — power = V·I, energy = V·Q, impedance = V/I.
Current (symbol I, unit the ampere) is the flow of charge, with charge Q in coulombs (I = dQ/dt). Schematics and datasheets use kA, A, mA, μA and nA: motor and supply currents are amps or kiloamps, a microcontroller’s quiescent current is microamps, and a high‑impedance input may draw nanoamps. The most common mistake here is misreading a datasheet’s “IQ = 250 μA” as 250 mA — a thousand‑fold error that shows up as a battery that drains far too fast. Always confirm the prefix on current specs, and remember 1 mA = 0.001 A = 1000 μA.
6. Resistance, conductance, resistivity & conductivity
Resistance (symbol R, unit the ohm, Ω) opposes current flow and is the most frequently prefixed quantity on a schematic: TΩ for insulation and ESD protection, MΩ for high‑impedance inputs, kΩ for the everyday bias and pull‑up resistors, Ω for current paths, and mΩ for shunts and ESR. Conductance (symbol G, unit the siemens, S) is simply the reciprocal, G = 1/R, so a 2 kΩ resistor has a conductance of 0.5 mS. You will meet siemens more in admittance and op‑amp feedback than in discrete part numbers.
Beneath the ohm sit two material properties. Resistivity ρ (ohm‑metre, Ω·m) describes how strongly a material resists current per unit geometry, and conductivity σ (siemens per metre, S/m) is its reciprocal, σ = 1/ρ. They relate to a physical resistor by R = ρ·L/A (length over cross‑section), which is why wire gauge matters: copper is roughly 1.68×10⁻⁸ Ω·m (about 5.8×10⁷ S/m). Watch the mΩ ESR quoted on modern capacitors and the MΩ insulation resistance quoted on cables — both are prefixes doing real work, and confusing mΩ with Ω overstates a loss by a factor of a thousand.
7. Power & energy (and the W vs Wh trap)
Power (symbol P, unit the watt, W) is the rate of energy transfer, P = V·I = I²R = V²/R, with prefixes MW, kW, W, mW and μW: a wall outlet is kilowatt‑class, a chip dissipates milliwatts, and a reference settles at microwatts. Energy (symbol E, unit the joule, J) is power integrated over time, E = P·t, and the joule is rarely big enough on its own — so we use the watt‑hour (Wh), where 1 Wh = 1 W × 1 h = 3600 J, and the kilowatt‑hour (kWh), where 1 kWh = 3.6×10⁶ J = 3.6 MJ, the unit your electricity bill is built on.
The most dangerous confusion on this list is W versus Wh. A watt is a rate (energy per second); a watt‑hour is an amount of energy. A 5 W LED and a 5 Wh battery sound similar but are different kinds of quantity — the LED tells you how fast it uses energy, the battery how much it stores. A 5 W load running for 2 h consumes 10 Wh. The same offset appears in charge: the ampere‑hour (Ah) is an amount of charge, not a current, and 1 Ah = 1 A × 3600 s = 3600 C, so 1 mAh = 3.6 C. Battery “capacity” (Ah) and battery “energy” (Wh) differ by the pack voltage: Wh = Ah × V.
Worked examples
- A 12 V battery rated 50 Ah stores 50 × 12 = 600 Wh = 0.6 kWh = 2.16 MJ of energy.
- A 0.5 W sensor running 24 h/day uses 0.5 × 24 = 12 Wh/day ≈ 4.38 kWh/year.
- A 1 mAh cell at 3.7 V holds 3.6 C of charge and 3.7 mWh (13.32 J) of energy.
8. Capacitance (F, μF, nF, pF)
Capacitance (symbol C, unit the farad, F) measures how much charge a component stores per volt, C = Q/V. A full farad is enormous for a discrete part, so real capacitors are almost always specified in microfarads (μF), nanofarads (nF) and picofarads (pF), each a thousand times smaller than the last: 1 μF = 1000 nF = 1,000,000 pF. Bulk and filter caps are μF, decoupling caps are nF (the ubiquitous 100 nF), and trimmer, timing and RF caps are pF. The stored energy is ½CV², which is why a large cap at high voltage can hold a dangerous charge even after power is removed.
The farad family is where prefix errors hurt most, because the steps are exactly 1000 and the symbols look alike in a hurry. 0.1 μF = 100 nF = 100,000 pF — a value you will see written all three ways. On SMD parts the code compresses this further: a 3‑digit code is the first two digits followed by a power of ten, so 103 = 10 × 10³ pF = 10,000 pF = 10 nF, and 104 = 100 nF. Reading 103 as 10 μF (a factor of 1000 high) is a real, recurring mistake. When in doubt, convert to a single prefix — usually μF or nF — before you calculate.
Worked examples
- 100 nF = 0.1 μF = 100,000 pF = 1×10⁻⁷ F.
- SMD codes:
103= 10 nF ·472= 4.7 nF ·220= 22 pF. - Two 10 μF caps in parallel = 20 μF; in series (equal values) = 5 μF.
9. Inductance & reactance (H, mH, μH, nH)
Inductance (symbol L, unit the henry, H) opposes changes in current and stores energy in its magnetic field, E = ½LI². Like the farad, a bare henry is large, so inductors are specified in mH, μH and nH, each 1000 times smaller: 1 mH = 1000 μH = 1,000,000 nH. Power‑supply chokes are μH to mH, RF and filter inductors are nH to μH, and the energy formula is why an inductor’s stored energy — and the voltage spike when you open its circuit — scales with the square of the current.
Inductance shows up in circuits through reactance, X, measured in ohms and frequency‑dependent: inductive reactance XL = 2πfL = ωL, and capacitive reactance XC = 1/(2πfC) = 1/(ωC). Together with resistance they form the impedance Z (ohms), |Z| = √(R²+X²), and its reciprocal the admittance Y (siemens), Y = 1/Z. Filter and matching design lives entirely in these units: a 10 μH inductor at 1 MHz has XL ≈ 62.8 Ω, and a 100 nF cap at 1 MHz has XC ≈ 1.59 Ω. Confusing μH with mH (a factor of 1000) silently moves every cutoff frequency by the same factor.
Worked examples
- XL of 10 μH at 1 MHz ≈ 62.8 Ω; at 100 kHz ≈ 6.28 Ω.
- RC low‑pass cutoff fc = 1/(2πRC): for 1 kΩ and 100 nF, fc ≈ 1.59 kHz.
- 1 nH = 0.001 μH = 10⁻⁹ H.
10. Frequency, angular frequency, period & wavelength
Frequency (symbol f, unit the hertz, Hz) counts cycles per second, and is prefixed kHz, MHz and GHz: audio is kHz, microcontrollers run at MHz, and Wi‑Fi and RF at GHz. Its twin is the period T (seconds), the time for one cycle, T = 1/f — so a 1 kHz signal has a 1 ms period. Wavelength λ (metres) ties frequency to the speed of light: λ = c/f, with c ≈ 3×10⁸ m/s, so a 100 MHz signal has a wavelength of 3 m. These three (f, T, λ) are the backbone of timing and RF work.
The trap here is Hz versus rad/s. Radians per second is angular frequency ω, not cycles per second; they differ by 2π: ω = 2πf, so 1 Hz = 2π rad/s ≈ 6.283 rad/s. Most textbooks write the reactance and filter formulas with ω (e.g. XL = ωL, fc = 1/(2πRC)), while your signal generator and a crystal are labelled in Hz. Plugging an Hz value into a formula that expects rad/s — or vice versa — is off by exactly 2π ≈ 6.283, a subtle error that does not look like a round power of ten and so slips through. When you see ω, multiply or divide by 2π to move to or from f.
Worked examples
- f = 60 Hz → ω = 2π × 60 ≈ 377 rad/s; T = 1/60 ≈ 16.7 ms.
- λ of 2.4 GHz (Wi‑Fi) = 3×10⁸ / 2.4×10⁹ = 0.125 m = 12.5 cm.
- 1 MHz = 1000 kHz = 10⁶ Hz; period = 1 μs.
11. The power triangle (W, VA, var, power factor)
In AC and switched circuits, power splits into three related quantities. Real (active) power P is in watts (W) and is the power actually converted to heat, light or motion. Apparent power S, in volt‑amperes (VA), is the product of RMS voltage and RMS current, |S| = Vrms·Irms. Reactive power Q, in volt‑amperes reactive (var), is the power that shuttles back and forth with inductors and capacitors. The three form a right triangle with |S|² = P² + Q², and the ratio pf = P/S = cos φ is the power factor, quoted as a number from 0 to 1 or as a percentage.
Two confusions cluster here. First, VA is not W: a 1 kVA UPS can deliver far less than 1 kW of real power if the load’s power factor is below 1 — at pf = 0.8, 1 kVA supplies only 0.8 kW. Second, var is not VA: var is the reactive component (the vertical leg, Q = |S|·sin φ), while VA is the total magnitude (the hypotenuse). A purely resistive load has Q = 0 and pf = 1, so its VA, W and real power all agree; the moment inductance or capacitance enters, the three separate. Always state which of the three you mean, and carry the power factor with any VA figure.
12. Magnetic quantities (flux, flux density, field strength)
Magnetic flux Φ (unit the weber, Wb, with 1 Wb = 1 V·s) is the total magnetic field passing through an area; flux density B (unit the tesla, T, with 1 T = 1 Wb/m²) is the flux per unit area. Both are heavily prefixed: transformer and motor flux is mWb to μWb, and field strength is mT to μT. For scale, a strong neodymium magnet is about 1.0–1.4 T at its surface, a refrigerator magnet a few mT, and the Earth’s field roughly 25–65 μT. Inductance links directly to flux: L = NΦ/I, and for a core, L ≈ N²·μ·A/l.
Magnetic field strength H is measured in ampere per metre (A/m) and is the “cause” (mmf per unit length), while B is the “effect” (flux density); they relate through permeability, B = μH, where μ is the material’s permeability. This is why a ferrite’s datasheet quotes μ (relative permeability, dimensionless) rather than a fixed inductance: the inductance of a coil on that core depends on μ, the cross‑section A and the magnetic path length l. Keep the three straight — H in A/m (field strength), B in T (flux density), Φ in Wb (total flux) — and remember the prefixes, since a 50 μT Earth field and a 50 mT motor gap differ by 1000.
13. Fields & material properties
Electric field strength E is measured in volts per metre (V/m), commonly prefixed to kV/m: it describes how strong an electric field is at a point, and appears in antenna and EMC work (a carrier at a few V/m is a strong near‑field), in PCB creepage/clearance calculations, and in electrostatics. It is distinct from voltage: voltage is a difference between two points (volts), while E is a field at a point (volts per metre). Likewise magnetic field strength H is in A/m, not amperes.
Material properties are quoted in per‑metre units and are easy to misread. Resistivity ρ is Ω·m and conductivity σ is S/m (σ = 1/ρ); a good conductor has tiny ρ and huge σ (copper ≈ 1.68×10⁻⁸ Ω·m, ≈ 5.8×10⁷ S/m). Dielectric and ferrite materials add relative permittivity εᵣ and relative permeability μᵣ (both dimensionless ratios), which scale capacitance and inductance. When a spec sheet gives a value in S/m or Ω·m, check the prefix — copper’s conductivity in MS/m (mega‑siemens per metre) is about 58, and dropping the “M” understates it by a million.
14. Time, temperature & physical dimensions
Time (unit the second, s) is prefixed ms, μs, ns and ps on schematics and in timing specs: gate delays are ns, setup/hold times are ns to ps, and an analog response might be quoted in μs or ms. Temperature uses three scales — kelvin (K, the SI base), degrees Celsius (°C) and Fahrenheit (°F) — with K = °C + 273.15 and °F = °C × 9/5 + 32, so absolute zero is 0 K = −273.15 °C = −459.67 °F. Component temperature coefficients are in ppm/°C, and derating curves are read in °C or K; note that Celsius and Kelvin share the same increment (a 10 °C rise is a 10 K rise) but not the same offset, so you add 273.15 rather than multiply.
Physical dimensions appear all over hardware. Length uses the metre with mm, μm and nm: PCB trace widths are mm to tens of μm, and IC feature sizes are nm. Area uses m² with mm², μm² (die area), and the imperial in² and the wire “mil²” (a mil is 0.001 in, so 1 mil² = 10⁻⁶ in²; the “circular mil” used in the AWG standard is π times a diameter squared in mils). Volume uses m³ with L and mL (1 L = 1000 mL = 1000 cm³). The recurring pitfalls are mixing a mil with a millimetre (1 in = 25.4 mm exactly, so 1 mil = 0.0254 mm), and treating a °C value as if it were K (a ratio vs an offset).
15. Confusing units & common pitfalls
Almost every unit error falls into one of three families: a prefix slip (k vs M, m vs M, μ misread as m), a dimension slip (treating a rate as an amount — W vs Wh, A vs Ah — or a magnitude as a component — VA vs W, VA vs var), and a scale slip (°C vs K offset, Hz vs rad/s, mil vs mm). The defense is a habit: before trusting any conversion, name the dimension of the quantity, check the prefix symbol’s case, and ask whether the unit is a rate, an amount, a magnitude, or a component. The comparison table below lists the pairs that cause the most real‑world mistakes.
A quick pre‑flight checklist: (1) Is the unit a base or a prefixed form, and which prefix? (2) Is this a rate (per second) or a total (over time)? (3) Is this the full magnitude or one component of a vector/complex quantity? (4) Does the quantity have an offset (temperature) rather than a pure ratio? (5) For AC, is power factor in play? Answering those five before you convert catches the vast majority of silent errors — and the interactive converter below gives you a second, arithmetic opinion on the result.
| Pair | Why they’re not the same | Correct relationship | Copy |
|---|---|---|---|
| W vs Wh | rate of energy vs amount of energy | 1 Wh = 1 W × 1 h = 3600 J; W = J/s | |
| VA vs W | magnitude of complex power vs real power | W = VA × pf; equal only when pf = 1 | |
| var vs VA | reactive component vs total magnitude | |S|² = P² + Q²; var = VA × sin φ | |
| Hz vs rad/s | cycles/s vs radians/s | ω = 2πf; 1 Hz = 2π rad/s ≈ 6.283 rad/s | |
| Ω vs S | resistance vs conductance | G = 1/R; 1 S = 1/Ω | |
| F vs μF/nF/pF | full farad rarely used; prefixes differ 1000× | 1 F = 10⁶ μF = 10⁹ nF = 10¹² pF | |
| H vs mH/μH | henry rarely used bare; prefixes differ 1000× | 1 H = 10³ mH = 10⁶ μH = 10⁹ nH | |
| C vs Ah | coulomb vs ampere‑hour | 1 Ah = 3600 C; 1 mAh = 3.6 C | |
| V vs mV/μV | volt vs prefixed volt | 1 V = 10³ mV = 10⁶ μV | |
| A vs mA/μA | ampere vs prefixed ampere | 1 A = 10³ mA = 10⁶ μA | |
| kΩ vs MΩ | kilo vs mega | 1 MΩ = 10³ kΩ | |
| °C vs K | offset scale vs absolute scale | K = °C + 273.15 (not a ratio) | |
| J vs Wh | joule vs watt‑hour | 1 Wh = 3600 J |
16. Best practice
Keep units attached to numbers at all times — write 4.7 kΩ, never a bare 4.7 — and convert to base units for intermediate math, then re‑express the final answer in a prefix that keeps the number between about 0.1 and 1000. Within a single design, pick one preferred prefix per quantity (kΩ for resistors, nF for decoupling, MHz for clocks) and stick to it, so a reader never has to mentally rescale from line to line. Dimensional analysis — checking that the base units (kg, m, s, A) balance on both sides of an equation — is a free correctness check that catches prefix and formula errors before simulation or fabrication.
Treat datasheets with a grain of salt on units: manufacturers sometimes omit the prefix, use engineering shorthand (“E3” for ×10³), or quote a typical value in a different prefix than the minimum/maximum. Convert the whole spec into one consistent unit before you design against it, and document any assumption. A silent unit error is the most expensive kind, because nothing fails loudly — the board simply does not meet spec, and the cause is a factor of ten hiding in a prefix. The tables, the converter and the self‑checking examples on this page are there to make that class of error rare.
Interactive unit converter
Pick a quantity, choose a value and a from/to unit (any SI prefix), and read the result. Temperature, energy, charge, area and volume include their non‑prefix units (°C/K/°F, Wh/kWh, Ah/mAh, in²/mil², L/mL). Copy the result for your notes.
SI prefix reference
The complete set of 24 SI prefixes plus the base (10⁰). Sort by column, search by name or symbol, and copy any symbol.
| Scientific | Decimal | Example | Actions |
|---|
Electrical quantity reference
Every major quantity with its symbol, SI/base unit, common derived units, typical prefixes and a conversion note. Filter by category or search.
| Symbol | SI / base unit | Common derived units | Typical prefixes | Conversion note | Actions |
|---|
No quantities match your search.
Technical references
- SI Brochure (BIPM, 9th edition, 2019) — the authoritative definition of the SI, its base units and the prefix set (including the 2022 additions quetta/ronna and quecto/ronto).
- IEEE 100 — The Dictionary of Electrical and Electronics Terms, for unit and symbol conventions.
- IEC 60027 — Direct current and alternating current, and the use of symbols for electrical quantities.
- Manufacturer datasheets for part‑family‑specific unit conventions (SMD codes, “E‑notation”, ppm/°C coefficients).
Accuracy note. All multipliers, scientific/decimal forms and conversion factors on this page are computed or cross‑checked (1 Wh = 3600 J, 1 Ah = 3600 C, ω = 2πf, K = °C + 273.15, |S|² = P² + Q²). Where a unit has more than one accepted form (e.g. the micro symbol μ), the Greek mu is used consistently. The interactive converter and the in‑page self‑test re‑verify these relationships on load.